The EBT720 is one of the most advanced, versatile and easy to use manometers on the market today. Auto-zeroing allows you to make measurements throughout the day. The optional velocity matrix is useful in measuring face velocity through filters, coils and other specialised spaces

Features:
  • Accurately measure pressure, velocity, and flow
  • Large, easy to read display
  • Data logging and downloading software included
  • Automatic density correction

Applications:
  • HVAC commissioning
  • Clean room certification
  • Troubleshooting HVAC systems
  • Testing & balancing HVAC systems
The EBT720 kit comes with:
Manometer, carring case, 4-AA size rechargeable NiMH batteries, multi-country ac adapter, 18" pitot probe, 2 static pressure probes, 16' neoprene tubing, downloading software, interface cable, manual and NIST traceable certificate.

Optional Accessories:

Description/Part Number
Airflow Probe
Airflow Probe Model 800187
18" (46cm) straight probe that can be used to perform a duct traverse and to measure face velocity
Velocity Matrix
Velocity Matrix Model 801090
Used to measure face velocities of HEPA filters, chemical fume hoods, laminar flow benches, filter banks, kitchen exhausts, and other applications where a large surface area needs to be measured. The 16 point grid covers one square foot area and averages the air velocity while minimizing the affects of turbulence to produce a stable reading.
Temperature Probe
Temperature Probe 800218
Telescopic probe extends from 9 to 40.5 inches (230 to 1030 mm) and can be inserted into a standard 5/16 in. (8 mm) diameter hole typically used for pitot traverses. Measures temperatures from -40 to 250°F (-40/121C)
Temperature/Humidity Probe
Temperature and Humidity Probe 800219
Telescopic probe extends from 9 to 39 inches (230 to 990 mm) and is ideal for measuring inside of duct work before and after a coil. Probe can be inserted  into a standard 5/16 in. (8 mm) diameter hole typically used for pitot traverses and can be used to calculate wet bulb and dewpoint temperatures.
Temperature Range: 14 to 140°F (-10/+60C)
Humidity Range: 0 to 95% RH ±3% RH

Specifications
Velocity Accuracy ±3% of full scale, all ranges
Static Pressure Accuracy ±5% of full scale, all ranges
Dimensions (Meter) 7.4" x 4.5" x 2.3"
Weight 17 oz (0.5 kg)
Velocity Ranges 25 to 15,500 ft/min (0.125 to 78 m/s) (with pitot probe or air velocity probe)
25 to 5,000 ft/min (0.125 to 25 m/s) with velocity matrix
Differential  Pressure Range ±15 inches of water (±3735 Pa)
Absolute Pressure
15 to 40 inches of mercury (356 to 1016 mmHg)
Pressure Accuracy
±2% of reading, ±0.001 inch of water (±0.25 Pa) static & differential
±2% of reading, absolute
Logging
Minimum, Maximum, Average up to 1000 readings, time & date stamped