DA/DS/DR Series Pressure Switches |
|
|
| Maximum Temperature | 180°F. For higher temperature media applications, a remote connection or syphon should be used. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Pressure Connection | 1/4" MNPT (1/2" MNPT on 15S range) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Housing | Pressure Steel with transparent cover (standard DA/DS/DR) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Wiring Connections | 3 screw type | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Maximum Pressure | Maximum adjustment range | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Electrical |
1: -153 circuit available 1A 440VAC on special order 2: Also rated 0.9 Amps at 24 VAC 3: 1/4 HP @ 120 VAC; 1/2 HP @ 240 VAC 4: DC Rated Controls (up to 10 Amps) available on special order 5: 5A, 30 VDC resistive 6: 17A non-inductive at 120/240/440 VAC |
|
Case Dimensions |
General Purpose NEMA 1 Enclosure
For infoor use and other general purpose applications under normal atmospheric conditions. Providess protection against dust and light splashing. Heavy gauge plain steel case. Flanged ase available. Transparent cover for visible on-off operation. Locking device prevents tampering. Bottom or back pressure connection, 1/4" NPT (1/2" NPT on 15S range). Electrical connection back of case for 1/2" conduit or BX. Shipping weight 4 lbs (2 kg.). Furnished as standard, unless otherwise specified. This enclosure is also suitable for Class I, Division 2 applications with the addition of a conduit hub (mercury switch models only). |
| Water Tight, Dust Tight - NEMA 3S, 4, & 4X Enclosure
For outdoor or indoor applications. Complies with hose test and requirements for water tight, dust tight, drip tight weatherproof, weather resistant, splash proof, sleet proof and moisture resistant. Flanged, heavy gauge steel case with transparent cover for visible on-off operation. External adjustments protected by cover. Bottom pressure connection only. Electrical connection back of case for 1/2" conduit, removable 1/2" hub. Shipping weight 6 lbs (3 kg.). |
|
| Explosion Proof - NEMA 7 and 9 Enclosure
Hazardous area enclosure suitable for Class I, Groups C & D, Class II, Groups E, F & G; NEMA 7 and 9 applications. Control mechanism is an integral part of the enclosure and cannot be replaced in the field. For surface, panel or pipe mounting. Aluminum case with glass window in cover for visible on-off operation. Bottom pressure connection. External adjustments. Available with breather and drain. Shipping weight 8 lbx (3.6 kg.). Not available on D80 series. |
| Example | DA | 70 | 2 | 1 | 153 | 7 | DA-7021-153-7 | ||||
| Reset Options | DA DR DR DS (note 3) DL (notes 1,3) |
U L |
Automatic
Reset, Adjustable Deadband Manual Reset, Fixed Deadband, Operates on decrease automatically Manual Reset, Fixed Deadband, Operatures on increase automatically Automatic Reset, Fixed deadband Manual lock reset, fixed deadband, available on special order only |
||||||||
| Housing &
Approval Options |
N3 |
See Note 7 |
W W H E |
F |
Weather
proof enclosure, Nema 3S, 4 and 4X. Flanged back standard Weather resistant, includes drain. Flanged back standard. Available as special order only. Explosion proof enclosure - control integral. Available only on DA, DR, DS Explosion proof enclosure - control removeable. Availe only on DA, DR, DS Factory Mutual Approval. DAW is FM approved as standard. |
||||||
| Circuit
Switching Options |
See notes 2 & 8
See note 12
|
2
|
2
3 153 156 804 2 3 4122 4129 4132 4123 2 3 153 804 153 804
B
|
|
SPST
opens on pressure increase. Elect. Code A, Mercury Switch SPST closes on pressure increase. Elect. Code A, Mercury Switch SPDT, Electrical Code B, Mercury Switch 2 each SPST, one opens as the other closes. Elect. Code A, Mercury Switch 2 each SPDT, Elect. Code B, Mercury Switch; Elect. Code G, Snap Switch SPST, opens on increase, Elect. Code I, DS only, Mercury Switch SPST, closes on increase, Elect. Code I, DS only Mercury Switch Two Stage Control, includes 2 each SPST Mercury Switch Two Stage Control, includes 2 each SPST Mercury Switch Two Stage Control, includes 2 each SPST Mercury Switch Two Stage Control, includes 2 each SPST Mercury Switch SPST, opens on increase, Elect. Code H, Mercury Switch SPST, closes on increase, Elect. Code H, Mercury Switch SPDT, Elect. Code D, Snap Switch 2 each SPDT, Elect Code F, for ranges above 35 PSI only, 702x, 703x, 704x only DS only SPDT Snap Switch, Elect code E 2 each SPDT snap switches, Elect code G, DS only Delrin Bushed Movement. For all controls |
||||||
| Ranges
and Bourdon Tube Materials |
See Note 6 See Note 6 See Note 6 |
2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 8 8 8 |
25S 26S 5S 6S 8S 9S 9AS 10S 11S 12S 13S 15S 16S 2 3 1 3A 4 27 5 6 7 8 9 26E 23E 6E 24E 9E 21E 22E 11E 13E 23K 24K 9K |
30"Hg
Vacuum - 60 PSIG, Type 403SS Bourdon Tube
30"Hg Vacuum - 75 PSIG, Type 403SS Bourdon Tube 2-60 PSIG, Type 403SS Bourdon Tube 5-100 PSIG, Type 403SS Bourdon Tube 10-200 PSIG, Type 403SS Bourdon Tube 10-300 PSIG, Type 403SS Bourdon Tube 40-350 PSIG, Type 403SS Bourdon Tube 25-600 PSIG, Type 403SS Bourdon Tube 50-1000 PSIG, Type 403SS Bourdon Tube 100-1500 PSIG, Type 403SS Bourdon Tube 300-2500 PSIG, Type 403SS Bourdon Tube 500-5000 PSIG, Type 403SS Bourdon Tube 800-8000 PSIG, Type 403SS Bourdon Tube 0-30"Hg Vacuum, Brass Bourdon Tube 10"Hg - 2 PSIG, Brass Bourdon Tube 1/8-15 PSIG, Brass Bourdon Tube 1/8-20 PSIG, Brass Bourdon Tube 1-35 PSIG, Brass Bourdon Tube 25"Hg - 50 PSIG, Brass Bourdon Tube 2-60 PSIG, Brass Bourdon Tube 5-100 PSIG, Brass Bourdon Tube 5-150 PSIG, Brass Bourdon Tube 10-200 PSIG, Brass Bourdon Tube 10-300 PSIG, Brass Bourdon Tube 30"Hg - 75 PSI, 316SS Bourdon Tube 5-75 PSIG, 316SS Bourdon Tube 10-100 PSIG, 316SS Bourdon Tube 10-150 PSIG, 316SS Bourdon Tube 10-300 PSIG, 316SS Bourdon Tube 30-400 PSIG, 316SS Bourdon Tube 75-800 PSIG, 316SS Bourdon Tube 100-1000 PSIG, 316SS Bourdon Tube 200-2500 PSIG, 316SS Bourdon Tube 5-75 PSIG, 316SS Bourdon Tube, Carbon Steel Bottom, F Housing Standard 10-150 PSIG, 316SS Bourdon Tube, Carbon Steel Bottom, F Housing Standard 10-300 PSIG, 316SS Bourdon Tube, Carbon Steel Bottom, F Housing Standard |
|||||||
| Connection
and Mounting Options |
1 2 3 4 |
Standard
Housing Back Connection. Not available for ranges 15S & 16S Flanged Back (Standard on W models) Back Connection and Flanged Back. Not Available for ranges 15S & 16S |
| Note 1: | Not available on D_ _ - _5, 74 or 95 |
| Note 2: | Available on DA only |
| Note 3: | Not available on D_ _ _ - 70_ _ |
| Note 6: | Available also as _ _28, 58, 708 and 728. Not available with E or H housing or 70-804 circuit. |
| Note 7: | F available only as DAF, DSF, DRF, DAHF, DRHF, DSHF; not all ranges or circuits. |
| Note 8: | Switch rating for D-400:
AC, 120V @ 0.3A; 240V @ 0.15A; 24V @ 0.8A DC, 120V @ 0.15A; 240V @ 0.07A Not available for 440V Service |
| Note 12: | Available only on 702, 703 and 704 |
Phone: 604-254-9622
Fax: 604-254-3123
e-mail: info@johnsherman.com