| The RLD10,
a portable, hand held refrigerant leak detector, offers Gases
that the unit can detect include: R11, R12, R13, R22, R23, R113, R114, R134A,
R500, R502, Halons, R404A, SF6, Perchlorethylene, Blends. |
| Power Supply: | One 9V Battery |
| Sensor: | Corona Discharge |
| Sensitivity: | 0.4 oz. (11 grams) per year; R134A using LS20 leak standard. |
| Indicators: | Audible: Variable tick Visual: scaled LED array |
| Warm up: | <10 seconds |
| Response Time: | <1 second |
| Duty Cycle: | Continuous |
| Battery Life: | Approximately 8 hours |
| Probe Length: | 18½ Inches (47 cm) |
| Ambient Operating Conditions: |
32 to 102°F (0 to 40°C); 0 to 80% RH (non-condensing) |
Phone: 604-254-9622
Fax: 604-254-3123
e-mail: info@johnsherman.com
www.johnsherman.com