| Selecable Inputs: |
Thermocouple, RTD, DC Voltage
or CD Current, Field Selectable |
| Display |
Two 4-digit, 7 segment,
0.25" high LEDs |
| Accuracy |
±0.25% of span, ±1
least significant digit |
| Supply Voltage |
100 to 240 VAC, nominal,
50 to 400 Hz. single phase; 132 to 240 VDC, nominal |
| Power Consumption |
5 VA maximum |
| Operating Temperature |
14 to 131°F
-10 to 55°C |
| Memory Backup |
Nonvolative memory. No batteries
required |
| Control Output Ratings |
AC SSR: 0.75A resistive
@ 240 VAC at 77°F (25°C), zero crossover fired. Derates to 0.5A
@ 130°F (55°C)
DC SSR: 1.25A @ 32
VDC maximum isolated. Derates to 1A @ 130°F (55°C)
Relay: SPDT, 3A @
240 VAC resistive; 1.5A @ 240 VAC inductive; Pilot Duty Rating: 250 VA,
2A @ 120 VAC or 1A @ 240 VAC
Current (Non-isolated):
0
to 20 mA (programmable) across 600 ohms maximum.
Switched Voltage (non-isolated):
5
VDC @ 20 mA |
| Weight |
4 oz. (114g) |
| Dimensions |
52.8mm wide x 30.1mm high
x 111.6mm deep |
|